| Specification |
|
Items |
Performance spec |
||
|
MAX, load current consumption (12 V) |
23.3 + 10% |
||
|
Input |
Communication frequency |
300 ± 5% |
|
|
Duty |
10, 30 - 90 % |
||
|
Voltage level |
HI |
more than 0.7 V |
|
|
LOW |
0 - 1.9 V |
||
Cooling Fan Components and components location
Cooling Fan Schematic diagramsHyundai Kona (OS) 2018-2026 Service Manual: ICM (Integrated Circuit Module) Relay Box Repair procedures
Inspection
Out Side Mirror Folding Relay
Check for continuity between the terminals.
1.
There should be continuity between the No.9 and No.19 terminals
when power and ground are connected to the No.10 and No.20 in the
ICM-B.
...
Hyundai Kona (OS) 2018-2026 Service Manual: SRS Control Module (SRSCM) Repair procedures
Removal
1.
Remove the ignition key from the vehicle.
2.
Disconnect the battery negative cable and wait for at least three minutes
before beginning work.
3.
Remove the floor console.
(Refer to Body ...